Where Do Engineering Firms Go Wrong With CAD File Security and Backup?
Most engineering firms back up their CAD files, but few can restore a full drawing set with its xrefs, prove who can open it, or recover from ransomware that reached the backup too.
That gap usually stays invisible until the week a project folder won’t open. This post walks through the common ways firms leave drawings exposed, and what to do about each one. For the wider IT picture, start with IT for engineering firms, and for day-to-day workstation, storage and licence support see CAD IT support in Ontario.
The stakes are not abstract. The Canadian Centre for Cyber Security recorded a 112% increase in ransomware incidents against professional services in Canada from 2022 to 2023, in its National Cyber Threat Assessment 2025-2026. And Statistics Canada reports that about one in six Canadian businesses with 10 or more employees (16%) were impacted by a cyber security incident in 2025.
Why Are CAD Files Harder to Protect Than Ordinary Office Files?
A CAD drawing is rarely one file. It depends on external references, image underlays, plot styles and sheet sets, so a backup only helps if every linked piece comes back together, from the same point in time.
Restore last night’s copy of a site plan and a three-day-old copy of the xref it points to, and the drawing opens with the wrong data in it. Nobody notices until a reviewer does. That’s why CAD backup has to be planned around project folders, not individual files.
Two other things catch people out:
- AutoCAD’s own .bak and .sv$ files are not a backup. Autodesk describes the .bak file as an exact copy of the drawing file prior to the last save, one per drawing, and autosave files are deleted when AutoCAD closes normally. They sit on the same disk as the drawing, so they disappear with it.
- Sync is not backup either. If a drawing is encrypted or deleted on one laptop, OneDrive or SharePoint sync copies the damage everywhere. Version history helps (Microsoft’s default for new libraries is 500 major versions, and deleted items stay in the site recycle bin for 93 days), but it isn’t a separate copy you control. Our guide to AutoCAD cloud collaboration explains which sync setups work for CAD and which break xrefs.
What Do Engineering Firms Get Wrong About CAD Backup and Security?
The common mistakes are structural, not exotic: relying on sync, keeping every backup on the same network, never testing a full project restore, and letting access drift as people and projects change.
The second row matters most. The Cyber Centre’s ransomware playbook warns that many ransomware variants are designed to locate, spread to and delete system backups, and it recommends keeping two or more backups offline and inaccessible from your network. A backup appliance in the same server room, joined to the same domain, is the kind of copy that warning is about.
How Should an Engineering Firm Back Up CAD Files?
Back up CAD files by project folder, on a schedule, to at least one copy the office network can’t reach. Keep several versions, store one copy offsite, and prove it works by restoring a full drawing set, xrefs included, on a regular schedule.
- List where live project files actually sit: server, SharePoint, Autodesk Docs or local drives.
- Back up whole project folders so drawings and their xrefs share one restore point.
- Follow 3-2-1: three copies, two kinds of storage, one kept offsite.
- Keep at least one copy offline or immutable, out of reach of office admin accounts.
- Keep enough versions to roll back past a problem nobody spotted for a week.
- Back up cloud project data too; sync and version history aren’t a separate copy.
- Test-restore a full active project every quarter and record how long it took.
Step 3 is the Cyber Centre’s own advice: its backup tips (ITSAP.40.002) recommend the 3-2-1 rule and a backup stored offline, because offline copies remain unaffected by many cyber threats. Step 7 is the easiest to put off. Timing it is the point: if, for example, restoring a 40 GB project takes nine hours over your internet connection, you want to know that before a submission date, not during one.
For the full backup plan behind these steps, see data backup best practices, and for the trade-offs between local and cloud copies, cloud backup vs local backup.
Who Can Open Your Drawings Right Now?
If the answer takes more than a few minutes to find, access has drifted. It builds up project by project, and it rarely gets taken away when someone changes teams, leaves the firm, or a consultant’s work ends.
Drawings and models are the firm’s intellectual property, and often a client’s confidential information as well. Three habits close most of the gap:
- Offboard everything on the last day. That means the Microsoft 365 account, file share permissions, remote access and the Autodesk seat. In Autodesk Account an administrator can unassign a user from a product under User Management, which removes access to the product. Products assigned through a group have to be removed at the group, so check that too.
- Turn on MFA for every account that can reach project files, including the Autodesk account and the remote access tools designers use from home. Our MFA implementation guide covers the rollout order.
- Send drawings deliberately. AutoCAD’s eTransmit packages a drawing with its xrefs and other dependent files for sharing, which beats attaching loose files. Fonts aren’t always included, so check the package before it goes. Use links that expire, and keep a record of what went to whom on each project.
Review project folder permissions when a project closes, not just when someone leaves. It’s a short job per project, and much easier than untangling five years of permissions later.
How Long Should an Engineering Firm Keep Project Drawings?
There’s no fixed legal period. Professional Engineers Ontario’s practice guideline says no law sets how long engineering documents must be kept, so each firm decides its own retention and disposal rules.
The PEO Professional Engineering Practice guideline (section 10.8) also suggests telling clients your retention policy and covering storage and destruction of project documents in the client agreement. That puts the decision with the principals, where it belongs. What IT can do is make sure the policy is actually carried out:
- Archive closed projects to storage that is backed up and tested, not to a USB drive in a drawer.
- Keep archived drawings in a format you can still open, and note which software release each project used.
- Apply the agreed retention period, and delete on schedule when it ends.
Talk to your lawyer and your insurer about the right period for your work. This is a summary of the guideline, not legal advice.
What Does a Good Recovery Look Like?
A good recovery is dull: you pick a restore point, bring back the whole project folder, check that the drawings and xrefs open, and the team is working again within hours rather than days.
The closest example from our own work isn’t an engineering firm. It’s a 35-person commercial painting contractor whose file server drives were failing, with the file share painfully slow. The previous provider quoted a $60,000 replacement. ACT360 turned that into a $25,000 fix: we replaced the failing drives before any data was lost and sized a server to bridge the firm to a planned move to the cloud (the full story is in the painting contractor case study). The lesson for a design firm is the same one: find the weak storage before it fails, not after.
If an attack does land, the order of the first steps matters as much as the backup. Our ransomware recovery plan sets out who does what, and in what order.
Where Does ACT360 Fit In?
ACT360 sets up and runs the backup, access and security side for engineering and design firms, then tests it, so principals see dated restore results instead of a reassuring dashboard.
For most firms that work sits inside a Managed IT agreement, priced per user, per month, from $65 to $180. Most organizations we support land between $80 and $100 per user. Every Managed IT agreement includes a 90-day exit clause. Our guide to IT support costs for engineering firms works through the numbers by firm size, and our business continuity and disaster recovery service covers recovery planning in more depth.
Final Thought
Ask your IT provider one question this week: when did we last restore a full project, xrefs included, and how long did it take? If nobody has an answer with a date on it, book a free IT Readiness Assessment and we’ll start there.